We provide homebuyer electrical surveys in Medway for buyers who need clarity on a property’s fixed wiring before exchange. We inspect the consumer unit, RCD protection, earthing, bonding, accessible cables, sockets and circuits, then record defects and likely remedial priorities. Most inspections cost £150–£350, depending on size, age and access, with repairs priced separately. While sellers aren’t legally required to obtain an EICR, landlords usually are. Continue below for costs, codes and local findings.

Electrician carrying out inspection and testing in a kitchen
Electrical inspection and testing
  • NICEIC approved
  • Part P registered
  • £5m public liability
  • 12-month workmanship guarantee
  • Fixed price before we start
Homebuyer Electrical Survey in Medway

What an EICR is and who needs one

An EICR is a formal inspection of a property’s fixed electrical installation, typically costing £150–£350 and taking 1–3 hours to complete.

We inspect fixed wiring, the consumer unit, circuits, sockets and protective devices to identify defects, deterioration and safety risks. We test and assess the installation against current safety standards and record observations that could affect electrical compliance.

If you’re buying a Medway home, an EICR helps us identify concealed issues before you commit, particularly in Victorian properties with older cable types or post‑war homes where aluminium wiring may be present. It isn’t required to sell a house, but it provides evidence of the installation’s condition.

Landlords must obtain a satisfactory EICR at least every five years, while homeowners should consider inspection frequency based on the age of the installation, any alterations, damage and occupancy. We also recommend an EICR after flooding, major building work or if you suspect electrical faults.

What an EICR costs in Medway

Typical EICR costs in Medway depend on property size; prices below include VAT, labour, testing and the certificate. We test protective devices, earthing, bonding, continuity, insulation and polarity and record observed defects.

Job Price What's included
Up to three bedrooms EICR £150–£250 VAT, labour, testing and the certificate; checks of protective devices, earthing, bonding, circuit continuity, insulation resistance and polarity; defect recording
Four or five bedrooms EICR £250–£350 VAT, labour, testing and the certificate; checks of protective devices, earthing, bonding, circuit continuity, insulation resistance and polarity; defect recording

Not included: remedial repairs, making good plaster or decoration, asbestos removal, DNO supply-upgrade charges, scaffold or specialist access equipment.

Do landlords in Medway need an EICR?

Private landlords in Medway should be aware that there is a legal requirement for most privately rented properties in England to have an Electrical Installation Condition Report (EICR) carried out by a qualified person at least every five years and before each new tenancy in certain circumstances; however, some exceptions apply (for example, houses in multiple occupation and specific contractual arrangements), so check current government guidance or ask Medway Borough Council for property‑specific advice. The inspection should assess the fixed electrical installation (consumer unit, circuits, protective devices, earthing and bonding, and socket circuits) for defects that could cause shock or fire, with observations recorded using the standard codes; any C1, C2 or FI findings will ordinarily require remedial work within the timescales specified in the report (commonly 28 days or sooner if stated), followed by written confirmation of completion. Landlords must provide the EICR to new tenants before they move in and to existing tenants within 28 days of the inspection, and supply it to the local housing authority within seven days if requested; failure to comply can lead to enforcement action and financial penalties under the Housing Act and related regulations, with maximum fines set by the authority in accordance with the legislation (penalty amounts can be substantial).

Do you need an EICR to sell your house?

No — there is no legal requirement in England for an Electrical Installation Condition Report (EICR) solely to sell a house in Medway. However, an EICR is often recommended where the installation’s age, condition or paperwork is uncertain because an inspection can identify defects such as damaged insulation, inadequate earthing, missing RCD protection, overloaded circuits and issues within the consumer unit.

A satisfactory report can give buyers clearer evidence of electrical safety and may reduce negotiation over unknown remedial costs; it can also help support a valuation where an older installation might otherwise raise concerns. An EICR is not normally a condition of mortgage approval, although lenders or surveyors may flag visible electrical defects and a buyer can request testing before exchange.

For Victorian homes, post-war properties or flood-affected installations, a detailed inspection is particularly advisable.

Do businesses need one?

Businesses have a duty under the Electricity at Work Regulations 1989 to ensure electrical systems are maintained so they do not give rise to danger, but the Regulations do not prescribe a fixed statutory interval for commercial EICRs (fixed‑wire testing). The commonly quoted intervals — five years for offices, three years for industrial premises and annual for certain high‑risk locations — come from IET Guidance Note 3 and are guidance rather than legal deadlines; the appropriate frequency depends on the nature of the premises, how equipment is used, the environment, any alterations and findings from previous reports. An EICR for your Medway business provides documented evidence that you are managing electrical risk and supporting fire safety, and insurers, commercial landlords and licensing bodies often require a current EICR as a condition of cover or occupation, so letting one lapse can affect compliance evidence or insurance terms. Plan testing around operational needs to minimise disruption and protect business continuity, and keep reports, records of remedial work and certificates available for inspection.

What we check

We assess the installation’s visible condition and carry out appropriate testing to identify safety concerns before you commit to a purchase. - Consumer unit, protective devices, earthing and bonding - Cable condition, insulation resistance, sockets, switches and accessories - Overheating, damage and signs of unsafe DIY alterations

We’ll explain any observations clearly, including issues that may need remedial work or further investigation.

The consumer unit and protective devices

At the consumer unit, we check that protective devices are correctly selected, labelled and operating as intended. We inspect the enclosure’s condition, access, blanking plates, circuit schedule and signs of overheating, corrosion, walderslade connections or unsuitable alterations. We identify older fuse boxes and assess whether their fuses, switches and protective arrangements remain appropriate for the installation’s present use.

We test RCDs and RCBOs where safe to do so, confirming disconnection performance and checking that circuit allocation supports safe fault protection. We also examine whether overcurrent devices match conductor sizes and whether unused ways are safely secured. Where fitted, we check surge protection devices for correct installation and visible status indication. Any missing labels, damaged components or evidence of overheating is recorded clearly, helping you understand urgency and likely remedial work before purchase.

Earthing and bonding

Earthing and bonding are critical to shock protection, so we inspect the main earthing arrangement, earthing conductor and main protective bonding to incoming metal services where present. We identify the supply earthing type, confirm that connections are accessible, secure and correctly sized, and check that clamps are labelled and fitted on the consumer’s side of any insulating section or meter.

Where safe and appropriate, we carry out tests to establish earthing resistance and verify that protective measures can operate within required disconnection times. We also assess bonding integrity at water, gas and other extraneous-conductive-parts, noting absent, walderslade, corroded or undersized conductors. In older Medway properties, alterations to plumbing can leave services unbonded, so we’ll flag defects that could increase touch-voltage risk.

Cable condition and insulation resistance

Cable condition gives a clear indication of an installation’s age, safety and likely remaining service life. We inspect accessible wiring for cracking, brittleness, overheating, mechanical damage, poor support and unsuitable alterations. In Medway’s Victorian terraces, we’re alert to old rubber or VIR-insulated cable; on post-war estates, we also consider the risks associated with aluminium conductors.

We carry out insulation testing, where safe and appropriate, to measure resistance between conductors and earth. Low readings can indicate deteriorated insulation, moisture ingress, contamination, damaged cable or concealed connection faults. We isolate sensitive equipment before testing and explain any limitations where circuits cannot be fully tested. Cable ageing doesn’t automatically mean immediate replacement, but degraded insulation can increase electric-shock and fire risk. Our findings help you understand whether repairs, further investigation or partial rewiring should be budgeted before purchase.

Sockets, switches and accessories

Alongside cable testing, we inspect sockets, switches, ceiling accessories and visible connection points for damage, overheating, walderslade fixings, cracked faceplates, poor-quality alterations and signs of overloading. We check that accessories are securely mounted, correctly positioned and suitable for their location, including kitchens, bathrooms and utility areas.

We assess whether socket circuits provide adequate coverage for modern use, reducing reliance on extension leads and adaptors. We also note inconsistent accessory types, obsolete fittings and installations that may compromise socket longevity or indicate incomplete alterations. Switch operation, plate alignment and fixing condition are recorded, while switch aesthetics are considered separately from electrical suitability. For a buyer, these observations help distinguish straightforward accessory renewal from work requiring further investigation. Where accessible, we identify whether visible connections appear properly enclosed and protected from accidental contact.

Signs of overheating, damage or DIY work

We check for heat discolouration, scorching, melted insulation, brittle cable coverings, damaged enclosures and burning smells that can indicate overloaded circuits, walderslade connections or previous faults. These defects can create electrical hotspots behind accessories, within consumer units or at cable joints, so we inspect accessible wiring routes and terminations carefully.

We also look for unsafe DIY alterations, including unsupported cables, incorrect connections, mixed cable types, missing covers, unsuitable junction boxes and circuits extended without appropriate protection. In Medway’s older homes, rubber, VIR or aluminium wiring may need closer assessment where age-related deterioration is visible. We’ll note impact damage, moisture ingress and signs that a repair has concealed a defect. Where safe testing is possible, we use results alongside visual findings to identify concerns requiring repair, further investigation or an EICR before you commit.

What the codes mean

We’ll explain each EICR observation code so you can judge the safety implications before committing to a purchase.

Code Meaning Required response
C1 Danger present; immediate risk of injury. Make safe without delay.
C2 Potentially dangerous condition. Arrange urgent remedial work.
C3 Improvement recommended; not immediately unsafe. Consider upgrading.
FI Further investigation needed to determine safety. Investigate promptly.

A C1, C2 or FI outcome means the installation is unsatisfactory, while a C3 alone doesn’t make it unsatisfactory.

C1, C2, C3 and FI explained

An EICR records observations using standard classification codes, helping us distinguish between an immediate danger and an item that should be improved. C1 means danger is present: we’ll advise immediate remedial action, such as making exposed live parts safe. C2 identifies a potentially dangerous condition requiring urgent correction, for example inadequate earthing or a damaged accessory.

C3 is an improvement recommendation. It doesn’t make the installation unsatisfactory alone, but you should consider it when budgeting, particularly with historic wiring or planned aluminium upgrades. FI means further investigation is required because testing or inspection cannot confirm safety; concealed defects, inaccessible circuits or inconsistent results may need additional work.

A C1, C2 or FI normally produces an unsatisfactory EICR. We’ll explain each observation, its location, risk and recommended remedial work before you commit to purchase.

How long it takes and what we need from you

Most homebuyer electrical surveys in Medway take around two to four hours, depending on the property’s size, age and access to the consumer unit, circuits and fixed equipment. Larger homes, extensions, outbuildings and older installations may require longer, particularly where wiring routes or protective devices need closer inspection.

For straightforward appointment logistics, please arrange access with the seller, agent or occupier and make certain electricity is connected. Our access requirements include clear entry to the consumer unit, meters, sockets, switches, loft spaces, garages and any fixed equipment we need to inspect. We may need to isolate circuits briefly for safe testing, so computers, alarms and sensitive equipment should be identified beforehand. Please provide any previous electrical certificates, alteration records and details of known faults. We’ll work methodically, minimise disruption and explain any access limitations recorded during the survey.

What happens if it fails

A failed electrical survey won’t necessarily stop a sale but can delay completion by up to 28 days and may incur remedial costs typically between £250–£2,000 depending on severity.

If a homebuyer electrical survey identifies unsatisfactory or potentially dangerous conditions, we’ll explain the observations clearly, record their severity and provide a written quotation for any remedial work. We’ll distinguish urgent hazards, such as exposed live parts, overheating connections or missing protective measures, from defects requiring planned attention.

You can use the findings when renegotiating the purchase price, asking the seller to arrange repairs, or budgeting after completion. Our remediation options may include replacing damaged cable, correcting earthing and bonding, fitting appropriate RCD protection, repairing accessories or upgrading an unsafe consumer unit.

We’ll advise where circuits should be isolated until repaired and what certification is needed once work is complete. Although a failed survey doesn’t automatically prevent a sale, unresolved defects can have insurance implications, especially where known risks contribute to damage, fire or injury.

Recent EICRs near Strood

In Strood itself, where many properties are 1930s and 1950s semi‑detached and terraced houses, we frequently find incomplete RCD protection on circuits added during later kitchen or bathroom refurbishments.

It can identify defects requiring correction before occupation, allowing you to assess electrical risk for that particular Strood property and plan remedial work appropriate to its age and type.

What it costs

JobWhat is includedPrice inc. VAT
EICR, up to 3-bedFull inspection, test results and report£150–£250
EICR, 4–5 bedFull inspection, test results and report£250–£350
PAT testingMinimum visit £80from £1.50/item
Consumer unit (fuse box) replacementBoard, RCBO/RCD protection, testing, certificate£500–£700
Fault findingMost faults traced in 1–2 hours£80/hr

All prices include VAT, parts, labour, testing and the certificate. Not included: making good plaster and decoration, asbestos removal, DNO charges for a supply upgrade, scaffold or access equipment. Fixed price in writing before we start — the bill is never larger than the quote.

Frequently asked questions

Do I need an electrical safety report when buying a house?

No — an EICR is not legally required for home purchase, but it can reveal unsafe consumer units, damaged fittings, or poor earthing and help with negotiations or repair planning.

Will an EICR find old wiring problems?

Yes — the report will note age-related wiring and any issues found at inspection, though it can’t guarantee hidden cables are defect-free.

Does an EICR tell me what needs fixing before I move in?

Yes — it ranks observations and limitationssso you can tell immediate dangers from items to budget for before occupation.

Do landlords legally need an EICR for rental homes?

It depends — landlords must meet electrical safety duties and provide valid EICRs at required intervals in many areas; check local landlord rules.

Will my home insurance require electrical certificates?

Yes — insurers may ask for evidence that known electrical defects were fixed, so keep reports and certificates with your insurance records.

Can I get an EICR for a listed or historic house?

Yes — inspectors will consider suitable routes and methods before recommending alterations to preserve the building while addressing safety.

Get a fixed price

Get a written fixed price for your Medway homebuyer electrical survey before we attend. We’ll confirm the fixed fee in writing after establishing the property type, size, number of consumer units, outbuildings and any known alterations. This allows us to allocate sufficient inspection time and include the appropriate report and certificate costs.

Call 07366 354 116 · 24hr